← All devices

RF + Microcurrent · Handheld

메디큐브 AGE-R 울트라튠 40.68

40.68 MHz radiofrequency combined with microcurrent for firmness.

medicube (APR)

Manufacturer claimCollagen boosting, firmness

Technology evidence

—

Multi-function — the contributing technology cannot be separated

Product evidenceNo public product-level study found
Research protocol matchUnknown
RegulatoryUnknown

Decision snapshot

Price₩698,000
Technology categoryRF + Microcurrent (multi)
Technology evidenceNo grade
Product evidenceUnknown
Dose disclosurePartial (2/6)
Protocol matchUnknown
Time burdenUnknown
Consumable lock-inUnknown
ManufacturingKorea

Separate signals only — no combined score.

Technology

RF (radiofrequency) · general tech evidence B

Radiofrequency current heats the dermis to trigger collagen contraction and remodelling

Microcurrent · general tech evidence D

Micro-ampere currents intended to stimulate facial muscle and cells

Dose transparency · Partial (2/6)

RF · Frequency40.68 MHz
RF · Output / energyNot disclosed
RF · Target temperatureNot disclosed
Microcurrent · Current (µA/mA)Not disclosed
Microcurrent · WaveformNot disclosed
Microcurrent · Frequency40.68 MHz

Undisclosed values are never estimated; “Not disclosed” is itself information for comparison.

Evidence

RF (radiofrequency) B — Home RF has a randomised split-face controlled trial (2022, 12 weeks, cosmetic on the other side) and an intraindividual controlled trial (2024) reporting wrinkle and dermal-thickness improvement. Output, temperature and protocol differ by device, so results do not transfer to a given product as-is.

Microcurrent D — Cell studies and small before/after series exist, but controlled randomised trials on skin ageing are scarce and protocols vary; reviews conclude more rigorous trials are needed.

Product grade (studies of this model only): A ≥2 independent RCTs (30+ each) · B one RCT or two controlled studies · C uncontrolled, small or maker-linked. Without them the technology grade is shown, except for multi-function devices and LED without published wavelengths. Without a published dose, study results cannot be assumed to apply to this product.

Technology evidenceMulti-function — the contributing technology cannot be separated
Product evidenceUnknown (no study of this model)
Research protocol matchUnknown
Can the effect be attributed to one technology?No — multi-function, cannot be separated

Protocol match detail

FrequencyUnknown
CurrentUnknown
Treatment timeUnknown
Treatment frequencyUnknown

Actual output is not published, so the technology evidence cannot be assumed to apply to this product. Multi-function device studies are never reused as evidence for a single technology.

Clinical studies

Studies of this model

No public product-level study found. We will add any public study the maker points to.

Marketing claim vs evidence

ClaimManufacturer claim“Collagen boosting”
EvidenceNo public study found
Measured resultNone
Independent replicationUnknown

Mechanism vs result

Mechanism shownPartial
Biological effect shownUnknown
Visible cosmetic result shownUnknown

“It heats tissue” is not “a visible lift is proven”. Home devices run far below clinic power for safety.

An immediate “lifted” look may be muscle stimulation or swelling change; persistence is mostly unmeasured.

Outcome susceptibility to placebo / natural variation

High

This does not mean the product has no effect. It shows how easily the reported result could be influenced by expectation, time, swelling, hydration or measurement conditions.

No study compared against a control, so reported change cannot be separated from the factors below.

Natural skin variation · Hydration · Swelling · Lighting · Camera angle · Make-up · Weight change · Sleep · Menstrual cycle · Skincare used alongside · Massage effect

Before / after reliability

Unknown

A: controlled conditions + objective device measurement + blinded assessment · B: mostly controlled · C: partly · D: large lighting/angle differences · F: marketing image. Only photos checked for lighting, camera, angle, expression and distance are graded; photos alone never confirm an effect.

OWNER REALITY

What owners actually experienced

Loading…

TopicWhat the evidence saysWhat owners say
Effect
Satisfied with performance
Product evidence unknown · technology —No data
Use
Actual use (median)
Recommended protocol unknownNo data
Price
Owner fair price (median)
Current price ₩698,000No data
Service
Satisfied with support
Warranty unknownNo data
Not enough owner data yet.

Have you used this product? Share your experience. Answers are shown only as aggregates and no personal details are collected.

Owner answers are user reports, not findings. Verified and unverified answers are separated; under 10 responses only counts are shown, under 30 a small-sample note is added.

Treatment burden

Session time not confirmed from official instructions or a study protocol.

Must you keep using it to maintain results?Unknown
Consumable lock-inUnknown

If the effect is small, this time is a cost too. Maintenance needs are shown only when sourced.

Pricing

Retail price₩698,000List price
Estimated markupNot shown — no BOM or factory-cost basis

List price. Store and membership prices run lower (₩399,000 membership example) · 2026-10-02

“Estimated markup” is used only with a real BOM or factory-cost basis. This product has none, so no number is invented. The price premium above is a ratio of real retail prices.

What is inside typical build · estimated

  • RF oscillator and amplifier circuit
  • Metal electrode head
  • Temperature sensor (thermistor)
  • Control MCU and display
  • Li-ion battery
  • Housing and charging dock
  • (Some models) conductive gel
  • Micro-ampere current generator
  • Metal electrodes (spheres or bars)
  • Skin-impedance sensing (some models)
  • Control MCU
  • Housing
  • Conductive gel (consumable)

The usual build of devices using this technology — not a teardown of this product. The parts total (BOM) is not computed without a basis.

What are you paying for?

HardwareUnknown
CertificationUnknown
BrandUnknown
MarketingUnknown
DistributionUnknown
ConsumablesUnknown
Gap to cheapest in categoryUnknown

Not a cost breakdown. Undisclosed items stay “Unknown”.

Cheaper products in the same technology category

No cheaper product in this technology category yet.

Comparable technology category; dose similarity is mostly unknown. Output, wavelength and extras may differ. Equal grades mean neither side has stronger evidence.

Total ownership cost

Device₩698,000
Consumables (gel, pads, cartridges)Unknown
App / subscriptionUnknown
Battery replacementUnknown
1-year cost₩698,000
3-year cost₩698,000

Cost per studied protocol

No study of this model, so no cost per studied protocol is shown.

Cost per result is compared directly only between studies with the same endpoint, measurement method and duration. Ratios across different studies are not computed.

BUYING GUIDE

What to check before buying

Multi-function devices

With several technologies, the effect cannot be attributed to one of them.

Output per technologyCheck dose disclosure for each technology separately.
Studies of this modelMulti-function devices do not inherit technology evidence.

Evaluation criteria, not a product ranking.

Country · OEM/ODM

Brand🇰🇷 Korea
HQKorea
Made inKorea
Manufacturer(주)에이피알 계열 — 판매처 고시에 따라 (주)에이피알 또는 (주)에이피알팩토리로 표기
Battery made inUnknown
OEM / ODMIn-house

Brand nationality and country of manufacture can differ. Country and OEM are shown only when confirmed by product notices, manuals or import data; OEM structure is never inferred.

Safety · electrical

KCR-R-pg1-ME-UTUN

KC is electrical/radio conformity and is not a Korean medical-device approval number.

Official warnings not yet checked from the manual. Items to check for this technology: Burn / overheating warning · Metal implants / pacemaker contraindication · Use during pregnancy · Pacemaker / implanted electronics · Skin irritation

Medical device regulatory status

Korea MFDSNot confirmed — database not searched
FDAUnknown
CEUnknown
ClassUnknown

Clearance or certification is not proof of effect.

Clinical evidence

Studies of this model (graded)None
Claims and related-device studiesNone
Product evidenceUnknown

Issues

Report charging, battery, overheating, burns, app, electrode, LED, weak output, shutdowns or consumable recognition problems. Reports are reviewed before publishing and makers can reply.

Report a problem

A/S

WarrantyUnknown
Korea serviceUnknown
Repair availableUnknown
International warrantyUnknown
Return policyUnknown
Return difficultyUnknown · window ?d · opened Unknown · customer pays return Unknown · hygiene exclusion Unknown
Disclosure0/5

ASK OWNERS

Ask owners

Personal details are rejected automatically. Answers are owner experiences, not facts confirmed by AMS.

Sources

Checked 2026-10-02 · The same criteria apply to every product. Send corrections through the report page.