Israeli multipolar RF device with muscle activation (DMA).
TriPollar (Pollogen)
Manufacturer claimWrinkle reduction, jawline
Technology evidence
BSome effect across several studies
Product evidenceNo public product-level study found
Research protocol matchUnknown
RegulatoryUnknown
Decision snapshot
Price$699
Technology categoryRF
Technology evidenceB
Product evidenceUnknown
Dose disclosurePartial (1/3)
Protocol matchUnknown
Time burden5.0 h / 12 weeks
Consumable lock-inHigh
ManufacturingUnknown
Separate signals only — no combined score.
Technology
RF (radiofrequency) · general tech evidence B
Radiofrequency current heats the dermis to trigger collagen contraction and remodelling
Dose transparency · Partial (1/3)
Frequency0.85 / 1.0 / 1.15 MHz (±10%)
Output / energyNot disclosed
Target temperatureNot disclosed
Undisclosed values are never estimated; “Not disclosed” is itself information for comparison.
Evidence
RF (radiofrequency) B — Home RF has a randomised split-face controlled trial (2022, 12 weeks, cosmetic on the other side) and an intraindividual controlled trial (2024) reporting wrinkle and dermal-thickness improvement. Output, temperature and protocol differ by device, so results do not transfer to a given product as-is.
Product grade (studies of this model only): A ≥2 independent RCTs (30+ each) · B one RCT or two controlled studies · C uncontrolled, small or maker-linked. Without them the technology grade is shown, except for multi-function devices and LED without published wavelengths. Without a published dose, study results cannot be assumed to apply to this product.
Technology evidenceB
Product evidenceUnknown (no study of this model)
Research protocol matchUnknown
Can the effect be attributed to one technology?Yes — RF
Protocol match detail
FrequencyUnknown
Treatment timeUnknown
Treatment frequencyUnknown
Actual output is not published, so the technology evidence cannot be assumed to apply to this product. Multi-function device studies are never reused as evidence for a single technology.
Clinical studies
Studies of this model
No public product-level study found. We will add any public study the maker points to.
Related studies — other models (not used for this grade)
Home-use TriPollar RF device for facial skin tightening: clinical study results (Beilin, J Cosmet Laser Ther) (2011)
Study typeRelated / different-device study
Device testedTriPollar STOP (earlier model)
FundingUnknown fundingFunding not stated; listed on the maker’s site
Sample23
Duration6 weeks
Control · randomised · blindedNo · No · Unknown
MeasuredPeriorbital and perioral wrinkles
ResultAverage 41% periorbital wrinkle reduction after 6 weeks (+6 maintenance); single arm, no control
Source
Marketing claim vs evidence
ClaimManufacturer claim“Fewer wrinkles”
Evidence6 wk / 23 people / funding unknown
Measured result6 weeks · 23 people · no control · earlier STOP model · periorbital wrinkles −41%
Independent replicationNone
Mechanism vs result
Mechanism shownYes
Biological effect shownPartial
Visible cosmetic result shownPartial
“It heats tissue” is not “a visible lift is proven”. Home devices run far below clinic power for safety.
Outcome susceptibility to placebo / natural variation
High
This does not mean the product has no effect. It shows how easily the reported result could be influenced by expectation, time, swelling, hydration or measurement conditions.
No study compared against a control, so reported change cannot be separated from the factors below.
Natural skin variation · Hydration · Swelling · Lighting · Camera angle · Make-up · Weight change · Sleep · Menstrual cycle · Skincare used alongside · Massage effect
Before / after reliability
Unknown
A: controlled conditions + objective device measurement + blinded assessment · B: mostly controlled · C: partly · D: large lighting/angle differences · F: marketing image. Only photos checked for lighting, camera, angle, expression and distance are graded; photos alone never confirm an effect.
OWNER REALITY
What owners actually experienced
Loading…
| Topic | What the evidence says | What owners say |
|---|
| Effect Satisfied with performance | Product evidence unknown · technology B 6 weeks · 23 people · no control · earlier STOP model · periorbital wrinkles −41% | No data |
| Use Actual use (median) | Recommended 10 min × 2.5×/week | No data |
| Price Owner fair price (median) | Price not disclosed | No data |
| Service Satisfied with support | Warranty 12 months | No data |
Not enough owner data yet.Have you used this product? Share your experience. Answers are shown only as aggregates and no personal details are collected.
Owner answers are user reports, not findings. Verified and unverified answers are separated; under 10 responses only counts are shown, under 30 a small-sample note is added.
Treatment burden
Per session10 min
Sessions per week2.5
Initial protocol7 weeks
Total over 12 weeks5.0 h
SourceUser manual (face ~10 min, 2–3×/week, 6–8 weeks)
Must you keep using it to maintain results?Unknown
Consumable lock-inHigh · TriPollar non-conductive gel · generic substitute not stated
If the effect is small, this time is a cost too. Maintenance needs are shown only when sourced.
Pricing
Retail price$699Official store
Estimated markupNot shown — no BOM or factory-cost basis
“Estimated markup” is used only with a real BOM or factory-cost basis. This product has none, so no number is invented. The price premium above is a ratio of real retail prices.
What is inside typical build · estimated
- RF oscillator and amplifier circuit
- Metal electrode head
- Temperature sensor (thermistor)
- Control MCU and display
- Li-ion battery
- Housing and charging dock
- (Some models) conductive gel
The usual build of devices using this technology — not a teardown of this product. The parts total (BOM) is not computed without a basis.
What are you paying for?
HardwareUnknown
CertificationUnknown
BrandUnknown
MarketingUnknown
DistributionUnknown
ConsumablesRequired · cost unknown
Gap to cheapest in categoryUnknown
Not a cost breakdown. Undisclosed items stay “Unknown”.
Cheaper products in the same technology category
No cheaper product in this technology category yet.
Comparable technology category; dose similarity is mostly unknown. Output, wavelength and extras may differ. Equal grades mean neither side has stronger evidence.
Total ownership cost
Not disclosed
Cost per studied protocol
No study of this model, so no cost per studied protocol is shown.
Cost per result is compared directly only between studies with the same endpoint, measurement method and duration. Ratios across different studies are not computed.
BUYING GUIDE
What to check before buying
RF (radiofrequency)
Output and temperature control matter most; gels and other consumables drive running cost.
FrequencyRF devices differ in frequency and electrode design.
Temperature controlA temperature sensor and cut-off are safety features.
Gel and consumable costCheck whether only a proprietary gel works and what a year costs.
Treatment timeMultiply time per area by sessions per week.
Safety contraindicationsCheck implants, pregnancy and other contraindications in the manual.
Protocol evidenceSee whether the product’s instructions match a studied protocol.
Evaluation criteria, not a product ranking.
Country · OEM/ODM
Brand🇮🇱 Israel
HQIsrael
Made inUnknown
ManufacturerPollogen Ltd.
Battery made inUnknown
OEM / ODMUnknown
Brand nationality and country of manufacture can differ. Country and OEM are shown only when confirmed by product notices, manuals or import data; OEM structure is never inferred.
Safety · electrical
KC is electrical/radio conformity and is not a Korean medical-device approval number.
Official warnings not yet checked from the manual. Items to check for this technology: Burn / overheating warning · Metal implants / pacemaker contraindication · Use during pregnancy
Medical device regulatory status
Korea MFDSNot confirmed — database not searched
FDAUnknown
CEUnknown
ClassUnknown
NoteThe earlier STOP received FDA clearance in 2019 (company release). Vx 2’s own status is disputed across sources
Clearance or certification is not proof of effect.
Clinical evidence
Studies of this model (graded)None
Claims and related-device studies1
Product evidenceUnknown
Issues
Report charging, battery, overheating, burns, app, electrode, LED, weak output, shutdowns or consumable recognition problems. Reports are reviewed before publishing and makers can reply.
Report a problemA/S
Warranty12 months
Korea serviceUnknown
Repair availableUnknown
International warrantyUnknown
Return policy30-day money-back guarantee (official store)
Return difficultyModerate · window 30d · opened Unknown · customer pays return Unknown · hygiene exclusion Unknown
Disclosure2/5
ASK OWNERS
Ask owners
Personal details are rejected automatically. Answers are owner experiences, not facts confirmed by AMS.
Sources
Checked 2026-10-02 · The same criteria apply to every product. Send corrections through the report page.