← All devices

RF · Handheld

TriPollar STOP Vx 2

Israeli multipolar RF device with muscle activation (DMA).

TriPollar (Pollogen)

Manufacturer claimWrinkle reduction, jawline

Technology evidence

B

Some effect across several studies

Product evidenceNo public product-level study found
Research protocol matchUnknown
RegulatoryUnknown

Decision snapshot

Price$699
Technology categoryRF
Technology evidenceB
Product evidenceUnknown
Dose disclosurePartial (1/3)
Protocol matchUnknown
Time burden5.0 h / 12 weeks
Consumable lock-inHigh
ManufacturingUnknown

Separate signals only — no combined score.

Technology

RF (radiofrequency) · general tech evidence B

Radiofrequency current heats the dermis to trigger collagen contraction and remodelling

Dose transparency · Partial (1/3)

Frequency0.85 / 1.0 / 1.15 MHz (±10%)
Output / energyNot disclosed
Target temperatureNot disclosed

Undisclosed values are never estimated; “Not disclosed” is itself information for comparison.

Evidence

RF (radiofrequency) B — Home RF has a randomised split-face controlled trial (2022, 12 weeks, cosmetic on the other side) and an intraindividual controlled trial (2024) reporting wrinkle and dermal-thickness improvement. Output, temperature and protocol differ by device, so results do not transfer to a given product as-is.

Product grade (studies of this model only): A ≥2 independent RCTs (30+ each) · B one RCT or two controlled studies · C uncontrolled, small or maker-linked. Without them the technology grade is shown, except for multi-function devices and LED without published wavelengths. Without a published dose, study results cannot be assumed to apply to this product.

Technology evidenceB
Product evidenceUnknown (no study of this model)
Research protocol matchUnknown
Can the effect be attributed to one technology?Yes — RF

Protocol match detail

FrequencyUnknown
Treatment timeUnknown
Treatment frequencyUnknown

Actual output is not published, so the technology evidence cannot be assumed to apply to this product. Multi-function device studies are never reused as evidence for a single technology.

Clinical studies

Studies of this model

No public product-level study found. We will add any public study the maker points to.

Related studies — other models (not used for this grade)

Home-use TriPollar RF device for facial skin tightening: clinical study results (Beilin, J Cosmet Laser Ther) (2011)

Study typeRelated / different-device study
Device testedTriPollar STOP (earlier model)
FundingUnknown fundingFunding not stated; listed on the maker’s site
Sample23
Duration6 weeks
Control · randomised · blindedNo · No · Unknown
MeasuredPeriorbital and perioral wrinkles
ResultAverage 41% periorbital wrinkle reduction after 6 weeks (+6 maintenance); single arm, no control

Source

Marketing claim vs evidence

ClaimManufacturer claim“Fewer wrinkles”
Evidence6 wk / 23 people / funding unknown
Measured result6 weeks · 23 people · no control · earlier STOP model · periorbital wrinkles −41%
Independent replicationNone

Mechanism vs result

Mechanism shownYes
Biological effect shownPartial
Visible cosmetic result shownPartial

“It heats tissue” is not “a visible lift is proven”. Home devices run far below clinic power for safety.

Outcome susceptibility to placebo / natural variation

High

This does not mean the product has no effect. It shows how easily the reported result could be influenced by expectation, time, swelling, hydration or measurement conditions.

No study compared against a control, so reported change cannot be separated from the factors below.

Natural skin variation · Hydration · Swelling · Lighting · Camera angle · Make-up · Weight change · Sleep · Menstrual cycle · Skincare used alongside · Massage effect

Before / after reliability

Unknown

A: controlled conditions + objective device measurement + blinded assessment · B: mostly controlled · C: partly · D: large lighting/angle differences · F: marketing image. Only photos checked for lighting, camera, angle, expression and distance are graded; photos alone never confirm an effect.

OWNER REALITY

What owners actually experienced

Loading…

TopicWhat the evidence saysWhat owners say
Effect
Satisfied with performance
Product evidence unknown · technology B
6 weeks · 23 people · no control · earlier STOP model · periorbital wrinkles −41%
No data
Use
Actual use (median)
Recommended 10 min × 2.5×/weekNo data
Price
Owner fair price (median)
Price not disclosedNo data
Service
Satisfied with support
Warranty 12 monthsNo data
Not enough owner data yet.

Have you used this product? Share your experience. Answers are shown only as aggregates and no personal details are collected.

Owner answers are user reports, not findings. Verified and unverified answers are separated; under 10 responses only counts are shown, under 30 a small-sample note is added.

Treatment burden

Per session10 min
Sessions per week2.5
Initial protocol7 weeks
Total over 12 weeks5.0 h
SourceUser manual (face ~10 min, 2–3×/week, 6–8 weeks)
Must you keep using it to maintain results?Unknown
Consumable lock-inHigh · TriPollar non-conductive gel · generic substitute not stated

If the effect is small, this time is a cost too. Maintenance needs are shown only when sourced.

Pricing

Retail price$699Official store
Estimated markupNot shown — no BOM or factory-cost basis

“Estimated markup” is used only with a real BOM or factory-cost basis. This product has none, so no number is invented. The price premium above is a ratio of real retail prices.

What is inside typical build · estimated

  • RF oscillator and amplifier circuit
  • Metal electrode head
  • Temperature sensor (thermistor)
  • Control MCU and display
  • Li-ion battery
  • Housing and charging dock
  • (Some models) conductive gel

The usual build of devices using this technology — not a teardown of this product. The parts total (BOM) is not computed without a basis.

What are you paying for?

HardwareUnknown
CertificationUnknown
BrandUnknown
MarketingUnknown
DistributionUnknown
ConsumablesRequired · cost unknown
Gap to cheapest in categoryUnknown

Not a cost breakdown. Undisclosed items stay “Unknown”.

Cheaper products in the same technology category

No cheaper product in this technology category yet.

Comparable technology category; dose similarity is mostly unknown. Output, wavelength and extras may differ. Equal grades mean neither side has stronger evidence.

Total ownership cost

Not disclosed

Cost per studied protocol

No study of this model, so no cost per studied protocol is shown.

Cost per result is compared directly only between studies with the same endpoint, measurement method and duration. Ratios across different studies are not computed.

BUYING GUIDE

What to check before buying

RF (radiofrequency)

Output and temperature control matter most; gels and other consumables drive running cost.

FrequencyRF devices differ in frequency and electrode design.
Temperature controlA temperature sensor and cut-off are safety features.
Gel and consumable costCheck whether only a proprietary gel works and what a year costs.
Treatment timeMultiply time per area by sessions per week.
Safety contraindicationsCheck implants, pregnancy and other contraindications in the manual.
Protocol evidenceSee whether the product’s instructions match a studied protocol.

Evaluation criteria, not a product ranking.

Country · OEM/ODM

Brand🇮🇱 Israel
HQIsrael
Made inUnknown
ManufacturerPollogen Ltd.
Battery made inUnknown
OEM / ODMUnknown

Brand nationality and country of manufacture can differ. Country and OEM are shown only when confirmed by product notices, manuals or import data; OEM structure is never inferred.

Safety · electrical

KCUnknown

KC is electrical/radio conformity and is not a Korean medical-device approval number.

Official warnings not yet checked from the manual. Items to check for this technology: Burn / overheating warning · Metal implants / pacemaker contraindication · Use during pregnancy

Medical device regulatory status

Korea MFDSNot confirmed — database not searched
FDAUnknown
CEUnknown
ClassUnknown
NoteThe earlier STOP received FDA clearance in 2019 (company release). Vx 2’s own status is disputed across sources

Clearance or certification is not proof of effect.

Clinical evidence

Studies of this model (graded)None
Claims and related-device studies1
Product evidenceUnknown

Issues

Report charging, battery, overheating, burns, app, electrode, LED, weak output, shutdowns or consumable recognition problems. Reports are reviewed before publishing and makers can reply.

Report a problem

A/S

Warranty12 months
Korea serviceUnknown
Repair availableUnknown
International warrantyUnknown
Return policy30-day money-back guarantee (official store)
Return difficultyModerate · window 30d · opened Unknown · customer pays return Unknown · hygiene exclusion Unknown
Disclosure2/5

ASK OWNERS

Ask owners

Personal details are rejected automatically. Answers are owner experiences, not facts confirmed by AMS.

Sources

Checked 2026-10-02 · The same criteria apply to every product. Send corrections through the report page.